Inquiry
Form loading...

LM800P explosion-proof static pressure liquid level sensor

The hydrostatic level transmitter adopts a high-performance diffused silicon piezoresistive pressure sensor as the core measuring element to accurately measure the static pressure of the liquid that is proportional to the liquid level depth. This pressure signal is converted into a standard current or voltage signal output through a signal conditioning circuit, thereby establishing a linear correspondence between the output signal and the liquid depth, and achieving precise measurement of the liquid depth. This product features high precision and small size.

Its explosion-proof design strictly adheres to relevant safety standards and can be applied to flammable, explosive and other hazardous environments, providing a reliable safety guarantee for liquid level measurement in industrial production. In hydraulic and lubrication systems, it can precisely monitor the liquid level to ensure the stable operation of the system. In the fields of energy storage, wind power and hydrogen energy in the new energy industry, it can effectively deal with complex working conditions and ensure equipment safety. In the photovoltaic industry, it can provide precise data for the liquid level control of photovoltaic equipment. In the automotive manufacturing industry, it can also meet various liquid level measurement requirements, contributing to the efficiency and safety of automotive production.

- Supports arbitrary setting of liquid level alarm

- The static pressure measurement method is simple and convenient to install

- The multi-protection structure design ensures high protection capacity

- Diverse styles, suitable for various industrial occasions

- It is made of anti-corrosion stainless steel and is suitable for various occasions

    Product Applications

    1. Petroleum industry

    Application scenarios

    Oil storage tanks: Used for inventory management, trade settlement and high and low liquid level alarm of crude oil and refined oil products (gasoline, diesel).

    Wellhead device: Monitors the liquid level in the downhole or surface separator.

    Oil pipelines and pumping stations: Monitor the liquid levels of dirty oil tanks and buffer tanks within the station.

    Liquid level control in refining and chemical plants, such as atmospheric and vacuum distillation towers, reflux tanks, reactors, etc.

    2. Chemical industry

    Application scenarios

    Raw material/product storage tanks: Store various acids, alkalis, solvents, and liquid chemical raw materials.

    Reactor and synthesis tower: Control the liquid level during the reaction process to ensure the balance and safety of the chemical reaction.

    Separation tank and distillation column: Precisely control the liquid interface to ensure separation effect.

    3. Power Plants (Thermal/Nuclear)

    Application scenarios

    Deionized water tank/condensate water tank: Monitor the liquid level of boiler feed water.

    Acid/alkali tank: Liquid level measurement of acid and alkali storage tanks in water treatment systems.

    Condensate tank and expansion vessel: Collect and measure the condensate after the condensation of high-pressure steam.

    Slag silos and ash silos: Although the medium is particles/slurry, they can also be used to measure the material level (special treatment is required).

    4. Urban water supply

    Application scenarios

    Clear reservoirs/water storage tanks: Monitor the water storage capacity of urban water supply networks.

    Pumping station: Controls the start and stop of water pumps to prevent dry running or overflow.

    Water supply network pressure/liquid level monitoring points: Integrated into the network, they are used to monitor regional pressure and liquid levels in water towers/highland water tanks.


    5. Hydrological Exploration and water Conservancy Engineering

    Application scenarios

    Automatic monitoring stations for river, lake and reservoir water levels.

    Groundwater monitoring Wells: Long-term monitoring of dynamic changes in groundwater levels.

    Flood season early warning system: Real-time monitoring of water levels in key water areas to provide data for flood control decision-making.

    Seepage pressure monitoring of the dam body/dam foundation.

    technical parameters

    Parameter
    Specification
    Measurement range
    See the selection table
    Power supply
    24VDC, 12VDC
    Output signals
    Analog quantity/Communication/switch
    Load
    Analog signal 4-20mA≤500Ω; PNP/NPN≤100mA
    Compensation temperature
    -10 to 70°C
    Operating temperature
    -40 to 80°C
    Storage temperature
    -40 to 65°C
    Zero temperature drift
    ±1.0%FS
    Sensitivity temperature drift
    ±1.0%FS
    Overload pressure
    150%FS
    Mechanical vibration
    20g (20-5000HZ)
    Impact
    100g (11ms)
    Comprehensive accuracy
    0.5 grade
    Long-term stability
    ±0.2%FS/ year
    Response time
    0.1 to 1.0 seconds
    Insulation
    100MΩ/250VDC
    Material
    Low-copper aluminum alloy for the junction box; The liquid level probe is made of all-stainless steel cable with polyurethane wire
    Medium compatibility
    Compatible with various media of 304 stainless steel. Special media can be customized in terms of material