KATU SENSOR | PS710 Differential Pressure Digital Position Sensor
PS710 Differential Pressure Digital Position Sensor






A differential pressure-based digital position sensor is a novel positioning device that employs differential pressure detection principles combined with digital signal processing technology. Unlike traditional sensors, it accurately determines the position state by detecting changes in the pressure difference between its sensing surface and the workpiece, directly converting this physical quantity into a digital signal output.
Its core working principle is as follows: the sensor incorporates a high-precision MEMS differential pressure-sensitive chip. When the measured object approaches or moves away from the detection surface, a slight pressure difference occurs in the gas circuit. This change is captured by a dedicated conditioning chip and then subjected to multi-stage temperature compensation, nonlinear correction, and digital filtering by an integrated microprocessor, ultimately producing a stable, high-precision digital position signal.
|
Applicable fluid |
Dry air (with a filtration accuracy of 5 micrometers)) |
||||
|
Rated distance range |
0.05~0.30mm |
||||
|
Display/setting range (distance reference value) |
0~1000 |
||||
|
Minimum display unit (distance reference value) |
1 |
||||
|
OUT1 |
Rated pressure range |
0.0~1000.0kPa |
|||
|
Displayable range (pressure value) |
-100.0-1000.0kPa |
||||
|
Repeatability accuracy |
<0.020mm |
||||
|
Temperature characteristics (based on 25℃) |
<0.030mm |
||||
|
Hysteresis |
Can be adjusted from 0 (factory setting: 0) |
||||
|
OUT2 |
Rated pressure range |
0.0-1000.0kPa |
|||
|
Set pressure range |
-0.0-1000.0kPa |
||||
|
Minimum display/set unit |
10kPa |
||||
|
Repeatability accuracy |
±0.5%F.S. ±1digit |
||||
|
Temperature characteristics (reference at 25℃) |
±2%FS. |
||||
|
Hysteresis |
Can be adjusted from 0. |
||||
|
Withstanding pressure |
1200kPa |
||||
|
Detection nozzle |
01.5*9 |
||||
|
Consumption flow rate |
<30L/min |
||||
|
Electrical Specification |
Power supply Voltage |
For applications where it is used as a switch output component |
24V ± 10%, with fluctuation of less than 10% |
||
|
For the application scenarios where IO-Link devices are used |
DC 18-30V pulsating (p-p) 10% (inclusive) |
||||
|
Consumption current |
<30mA |
||||
|
Protection |
With reverse connection protection |
||||
|
Switch output |
Option for NPN/PNP collector open-collector output |
||||
|
Maximum load current |
10mA |
||||
|
Maximum additional voltage |
30.0V |
||||
|
Residual voltage |
Below 5V (10mA) |
||||
|
Short-circuit protection |
corresponding |
||||
|
Display mode |
14.4-inch color screen |
||||
|
Resistant to environmental conditions |
Protection level |
IP67 level is equivalent to |
|||
|
Operating temperature range |
During use: 0 - 50℃ When storing: -20 - 70℃ (no condensation, no freezing) |
||||
|
Operating humidity range |
During operation / When saving: 35 - 85% RH (no condensation) |
||||
|
Withstanding voltage |
Above 1000V 6 seconds, between all charging components and the housing |
||||
|
Insulation resistance |
Above 100 MΩ (with a DC 500V megohmmeter), between all charging components and the housing |
||||
|
Piping specifications |
For the occasions with pipe specification C |
Supply outlet |
Rc1/8 |
||
|
Detection port |
06 Quick-change connector |
||||
|
For the occasions where the pipe specification is F |
Supply outlet |
G1/8 (in accordance with ISO1179-1 standard) |
|||
|
Detection port |
G1/8 (in accordance with ISO1179-1 standard) |
||||
|
Cable |
Wire with connectors |
Wire with M12-4 connector, 4 cores, 045m Conductor outer diameter: 0.72mm, Insulator outer diameter: 1.14mm |
|||
|
Concentrated wire |
The wire with M12-4 connector has 4 cores and an outer diameter of the insulation: 1.14mm. The central conductor section from position 2 to 3: 8 cores with 0.65mm x 4~6 positions: 14 cores with 0.65mm The outer diameter of the conductor: 0.50mm, the outer diameter of the insulation: 1.00mm (common for positions 2 to 6) |
||||
|
Weight |
100g - 130g (excluding cables and quick connectors) |
||||
|
Specification |
CE Mark (·RoHS Directive) |
||||
|
Communication specification (When in IO-Link mode) |
IO-Link type |
Equipment |
|||
|
IO-Link version |
V1.1 |
||||
|
Communication speed |
COM2(38.4kbps) |
||||
|
Setting file |
IODD file |
||||
|
Minimum cycle time |
6ms |
||||
|
Process data length |
Input Data:12byte.Output Data:Obyte |
||||
|
Data communication request |
corresponding |
||||
|
Data storage function |
corresponding |
||||
|
Event Function |
corresponding |
||||
This is its primary application area, mainly used for measuring and controlling fluid parameters such as flow rate, level, and density—physical quantities often correlated with position or height.
Calculates fluid flow rate by measuring the differential pressure generated by throttling devices such as orifice plates and Venturi tubes. When combined with digital output, it can be easily integrated into DCS or PLC systems for precise flow monitoring and accumulation.
In a sealed container, the liquid level height can be determined by measuring the pressure difference between the bottom and top (or gas phase space) of the container. Digital sensors provide direct linear digital signals corresponding to the liquid level, which are used for storage tank monitoring, pump-valve interlock control, and similar applications.
At a constant liquid level, variations in differential pressure reflect changes in liquid density and are commonly employed in processes requiring solution concentration monitoring.
By measuring the differential pressure before and after the filter, an alarm is triggered when it exceeds a preset threshold to indicate the need for cleaning or replacement of the filter element, ensuring system safety.
In such systems, sensors are used to monitor and control the position or force state of actuating components (e.g., cylinders or hydraulic cylinders).
By measuring the pressure difference across the piston, the piston's position or whether it has reached the desired position can be indirectly determined. Digital output facilitates communication with a host computer, enabling closed-loop control.
Measures the pressure differential in actuating components caused by load variations; when the differential pressure exceeds the safety threshold, the system automatically triggers an alarm or shuts down.
In pneumatic or hydraulic valves, differential pressure feedback precisely controls the valve core position to achieve accurate regulation of flow rate or pressure.
In automotive systems, differential pressure sensors are commonly used for monitoring parameters related to position and flow.
By measuring the differential pressure before and after the DPF, its blockage severity is determined; if the pressure exceeds the threshold, a regeneration program is triggered.
Monitors the differential pressure before and after the EGR valve to precisely control the exhaust gas recirculation rate.
By measuring the pressure difference between the airbag interior and the external environment, it indirectly determines the vehicle's height (position) and automatically adjusts suspension stiffness.
Used for building environmental control to ensure stable air flow and spatial pressure.
In ventilation ducts, airflow is calculated by measuring the differential pressure across a pitot tube or flow nozzle, used for controlling VAV (Variable Air Volume) systems.
Maintain a slight positive or negative pressure between the cleanroom, operating room, or laboratory and adjacent areas to prevent cross-contamination.
Similar to industrial applications, it monitors the differential pressure across the air conditioning unit's filter and alerts when replacement is required.
It requires extremely high precision and cleanliness, while digital signals facilitate data recording and remote monitoring.
Accurately measures air flow differential pressure to monitor and regulate the patient's ventilation volume.
In the gas supply system, differential pressure is monitored to ensure the gas is delivered at the set flow rate.
Ensures the maintenance of the required pressure gradient in critical areas to guarantee operational safety.
For large-scale collection of infrastructure and environmental data.
At weather stations, wind speed is measured using specialized differential pressure sensing devices.
By monitoring the pressure difference in long-distance oil and gas pipelines, leakage locations can be identified.
Calculates water depth by measuring the pressure difference between the water surface and the seabed (or atmosphere), used for hydrological monitoring.
[KATU Electronics (Kunshan) Co., Ltd.] is a high-tech enterprise dedicated to the R&D, production, and sales of sensors and controllers. Our core product portfolio covers flow, pressure, temperature, liquid level, and position sensors, along with matching controllers. These products are widely applied in industrial automation, new energy, data centers, and intelligent manufacturing. Driven by technological innovation, we are committed to providing reliable sensing and control solutions to customers worldwide.

![Meeting the Cooling Imperative of the AI Era: [KATU] Full-Range Sensors Empower High-Quality Liquid Cooling Development.](https://ecdn6.globalso.com/upload/p/3850/image_other/2026-06/cover-9.jpg)
![[Katu Electronics (Kunshan) Co., Ltd.] Four-series sensors | CE dual certification](https://ecdn6.globalso.com/upload/p/3850/image_other/2026-06/cover-8.jpg)