PM270 Ceramic Capacitive pressure (level) transmitter
Product Applications
I. Chemical and Process Industry
Storage and transportation of highly corrosive chemicals
Application scenarios: Pressure and liquid level measurement of storage tanks for concentrated sulfuric acid, concentrated hydrochloric acid, caustic soda (NaOH), organic solvents, etc.
Reactor pressure monitoring
Application scenarios: high-pressure/high-temperature chemical reaction processes such as polymerization, nitrification, and oxidation.
Pipeline flow measurement
Application scenario: Calculate the flow rate of corrosive media by measuring the pressure difference before and after the throttling element (such as a orifice plate).
Ii. Water Treatment and Environmental Protection
Sewage treatment plant (aeration tank, dosing system, sludge treatment site) :
Application scenario: Monitoring the outlet pressure of the aeration blower; Monitor the inlet and outlet pressures of the sludge transfer pump and dosing pump.
Water level monitoring of rivers and lakes
Application scenario: Fix the submersible level transmitter underwater for long-term monitoring of water level changes.
Iii. Food, Beverages and Pharmaceuticals
Pressure monitoring of CIP/SIP cleaning process
Application scenarios: Monitoring the pressure of high-temperature cleaning solutions and saturated steam during online cleaning and online sterilization processes.
Measurement of high-viscosity media (syrup, jam) :
Application scenarios: Liquid level measurement in storage tanks, pressure monitoring in conveying pipelines.
Iv. Energy and HVAC
Boiler system, heat exchange station
Application scenarios: Monitoring boiler feed water pressure, steam pressure, and primary/secondary side pressure of heat exchangers.
Compressed air system
Application scenarios: Pressure monitoring of air compressor outlets, air storage tanks, dryers and pipeline networks.
V. Heavy Machinery and Hydraulics
Construction machinery, injection molding machines, presses
Application scenarios: Integrated into the hydraulic system, injection system or main oil circuit of the equipment, used for pressure feedback and control.
Vi. Research and Verification
Used as a standard meter or for laboratory measurement:
Application scenario: It is used as a pressure standard in the metrology room to calibrate other industrial pressure gauges. Measure the reaction pressure in precise laboratory experiments.
technical parameters
|
Parameter
|
Specification
|
|
Process connection
|
G1 external thread
|
|
Working voltage
|
DC18... 30V
|
|
Output signal
|
4... "20; (Adjustable range) mA
|
|
Measuring range
|
-0.1.. 1MPa
|
|
Compressive strength
|
5MPa
|
|
Burst pressure
|
15MPa
|
|
Lag deviation
|
<± 0,15; (Turn down 1:1) X21
|
|
Characteristic curve deviation
|
<± 0.2 (nach DIN EN 61298-2); (Including: drift, zero point and measurement range errors, nonlinearity, hysteresis caused by too tight installation; Turn down 1:1)X21
|
|
Long-term stability
|
<± 0,1; (Turn down 1:1; each year) X21
|
|
Linear deviation
|
<± 0,15; (Turn down 1:1) X21
|
|
Zero point of temperature coefficient
|
<± 0.05 (0.." 70°C) X22
|
|
Temperature coefficient range
|
<± 0,15; (0... 70°C) X22
|
|
Repeatability accuracy
|
<± 0.1; (Temperature fluctuation <10K; Turn down 1:1)X21
|
|
Electrical interface
|
M12 connector
|
|
Raw materials
|
Stainless steel (1.4404/316L), PBT
|
|
Material (damp components)
|
Ceramic (99.9% al2o3); PTFE; Stainless steel (1.4435/316L)
|
|
Surface characteristic value
|
Ra< 0,4 /Rz4
|
|
Enclosure protection grade
|
IP67; IP68;" IP69K
|
|
Protection class
|
III
|
|
Ambient temperature
|
-25... 80°C
|
|
Medium temperature
|