PS510 Electronic digital differential pressure sensor
Data Download
Product Application
Application in Sewage treatment plants
Air volume monitoring and control in aeration tanks
Application scenario: In the wastewater treatment process, the aeration tank needs to supply oxygen through forced air to maintain the activity of microorganisms.
Function: Measure the pressure difference before and after the aeration pipeline through a differential pressure sensor, calculate the air volume in combination with the flow formula, and adjust the fan speed in real time to ensure that the oxygen supply volume matches the sewage load.
Monitoring of the pressure difference between the inlet and outlet of the feed water pump
The feed water pump is used to supply water to the boiler. It is necessary to monitor the pressure difference between the inlet and outlet to determine the operating status of the pump.
Function: A sudden drop in pressure difference may indicate pump cavitation or pipeline blockage, while a sudden increase may indicate abnormal valve closure.
Advantages: Early warning of equipment failure, avoiding downtime losses, and extending the service life of the pump set.
Technical Parameters
Supply voltage |
12... 30Vdc |
No-load current consumption |
Maximum 40mA, powered by 24Vdc |
Switch output | |
Output type |
PNP/NPN switchable, normally open/normally closed adjustable |
Switching load |
< 200mA /24VDC |
Response time |
0.01 to 2 seconds (factory default) |
Switch accuracy |
≤±0.5% range |
Current-type analog output |
≤±0.5% range |
Output type |
4-20mA/1-5V/0-10V can be set |
Load RA |
≤500Ω |
Linearity |
≤0.5% range |
Communication output |
IO-Link/RS485 |
Wiring protection |
Reverse phase, overload, short circuit protection |
Display | |
Design |
Red 4-digit 12mm high-brightness LED |
Display range |
-1999... 9999 |
Accuracy |
≤±0.5% range |
Stability (annual drift) |
≤±0.3% range |
Temperature | |
Medium temperature |
-20... 85°C |
Ambient temperature |
-20... 80°C |
Storage temperature |
-30... 80°C |
Overload capacity |
2.5 times the full scale on one side |
Bilateral synchronous pressurization < 10MPa |
|
Materials | |
Meter head housing |
Engineering plastic |
Flame retardant grade |
UL-94 V-0 |
Shell |
Stainless steel 304 |
Medium contact part |
Stainless steel 304 |
Protection grade |
IP67 |
Cable exit method |
M12x1 connector |